Đang tải dữ liệu ...

Van 3 ba ngả

Giá bán: 1.386.000đ

Thông tin sản phẩm

Danh mục: Điện máy khác

Chủng loại: Khác

Liên hệ hỏi mua
Hỏi mua
Xem số ĐT
0906631316
Chưa cập nhật
Lưu lại tin này
Liên hệ : 0838484949 ; 0978564513  VAN 3 NGẢ 

 

Brief Instruction:

This series of Motor Valve is used for the control of the ends of center A/C. Thermostat control the motor of the Valve, and make on/off through speed-down machine and reset spring to carry out the break/on of the hot/cold water in the pipe.

Main Specification:

  • Forging brass valve body
  • Stainless steel base, aluminum shell
  • Totally enclosed uni-directional hysteresis synchronous motor drive, stainless steel spring return
  • Electric valve is divided into normal close 2-way valve and bypass the 3-way valve
  • Motor voltage and valve body to take over the form can be custom made

Main Specification

  1. Power supply: 220V +/- 10% 50Hz~60Hz
  2. Power: <6.5W
  3. Pressure: 1.6MPA
  4. Valve Action time:

open time ≤13s        closing time ≤7s

5. Working Circumstance:

Air temperature: 5~40℃

Pipe water fluxion temperature: 5~90℃

 

6. Type, Model, Turnover Capability refer the table:

Product size:

Figure 1, figure 2 is to use tools to dissect the electric valve installation size figure shape.

D

Refer table for the product size:

 

Instruction of operation and Installation:

1. Feed line and return pipe of differential pressure should be controlled within the range allowed pressure difference.

2. The valve should be installed somewhere easy to install and maintain.

3.  Horizontal installation, that’s mean the motor should be in the above of valve body to avoid humidity.

4. When install 2 way valve, B side should be infall and A side should be outfall (A, B signed on the bottom of valve body)

5. When install 3 way valve, infall is on the bottom of valve (no signal showed)

Pay attention to

The 3 way valve, B side is NC and a side is NO, so install outfall pipe, B side should be connected with main pipe and A side should be connected with by pass pipe, please refer to figure 3.

Open valve manually, should push operation pole out softly, when operation pole is on the above of block ora, push down softly and make operation pole just on the place of block ora, now the valve is just on the station of full connect. Poke operation pole up, the valve could auto reset through spring revert power, the valve could work normal again.

Thông tin shop bán
EngineerViet
Nhắn cho người bán
  • Địa chỉ Chưa cập nhật
  • Điện thoại Chưa cập nhật
  • Hotline 0906631316
Bình luận (0)
    Lưu sản phẩm
    X